<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-14 05-21-28
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
107.80 MHz 5/5, 53 dBuV P2 SR
Pilot RDS Phase Difference
7.3 kHz 5.7 kHz 1 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
14 kHz 24 kHz 19035 0,0053
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-5,9 dBr -4,06 dBr -2,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"P2 SR " E402 14 (Classics) 0 1 1 9 4:21, 14.12.2024
RT
"Notturno "
AF EON
91.7, 93.6, 94.5, 97.5 MHz E203, E224, E201
FM Scope Max at: 24 kHz MIN: 14 kHz % above 76 kHz: 0,0053 Acquired: 2024/12/14 5.20.24 Total samples: 19035 Equivalent time: 0:15:51 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: -2,3 dBr MIN: -5,9 dBr AVE: -4,06 dBr % above 12,2 dBr: 0,0 Last value: -4,0 dBr (2024/12/14 5.20.24) 05.06 05.08 05.10 05.12 05.14 05.16 05.18 05.20 0 50 100 Dev. MAX [kHz] -6 -4 -2 0 Pm [dBr]